SMX-QS04-B Interferometer

SMX-QS04-B is a high-end blue light interferometer with high resolution for inspection of single fiber connectors ST, FC, SC, LC, MU, E2000 (PC and APC), MIL-ST (M83522/16, MIL-C-83522), M29504/14 (MIL-PRF-29504/14) and other connectors.

This interferometer's compact size is ideal for facilities with limited bench space. The objective is built integrated inside the stage, which provides extreme vibration resistance. No vibration damping table is needed and device can work in a noisy manufacturing or repair facility. SMX-QS04-B features autofocus with long range, which simplifies and speeds up the measurement procedure.

Features

High resolution optics

Resolve surface details as small as 0.53 µm.

High resolution 2D/3D surface profiles

The 3D surface view enables you to see the volume image of the fiber and the ferrule. Explore surface details.

Wide range of fixtures

Inspect single-fiber connectors, ferrules, bare fibers, MS termini, both PC and APC.

High contrast optics

Inspect connnectors made of different materials (glass, metal, plastic) and buffer zones.

Compliance to industry standards

Test per IEC, Telcordia or your own Pass/Fail criteria.

Automated inspection software

Measure radius of curvature, apex offset, fiber height, etc.

Configurable report generation and data archival

Document your results your way.

 

Specifications

Specification

System

Measurement technique:
non-contact; Phase Shift Mireau interferometry

Lens:
NA=0.52; reference flatness error < λ/50

Illuminator:
blue LED (450 nm)

Field of view:
d=0.4 mm

Lateral resolution:
0.53 µm

Magnification:
900× (the digital zoom turned off)

Focus:
auto

Maximum image size:
2590 × 1940 px

Best suitable for connectors/ferrules (PC and APC):
SC, FC, ST, LC, MU, E2000

Measurement

Measurement mode:
phase shift

Measurement range:
Radius of curvature: 1 mm – flat
Apex offset: 0 - 250 µm

Scanning and calculation time:
Measurement time doesn't include time for auto focus; may vary depending on computer performance and connector end face shape.
3.5* - 21** sec (single fiber)
* High Speed mode, Monochrome 9 Frames algorithm, 55MHz (standard connector)
** High Precision mode, Monochrome 50 Frames algorithm, 55MHz (standard connector)

Repeatability C.F.*:

*Values calculated from 30 consecutive measurements without interaction on connector between measurements (connector fixed).
ROC: 0.03 %
Fiber Height: 0.17 nm
Angles: 0.0004 deg
Apex Offset: 0.06 µm

Repeatability C.R.*:

*Values calculated from 30 consecutive measurements with removing and inserting connector between measurements (connector reloaded).
ROC: 0.06 %
Fiber Height: 0.2 nm
Angles: 0.003 deg
Apex Offset: 0.6 µm

Recommended Environment

Temperature:
+20°C… +24°C

Pressure:
700 – 850 mm mercury

Humidity:
5 – 95%, non-condensing

Dimensions and Weights

Dimensions (H × W × L):
110 × 145 × 240 mm (4.33 × 5.7 × 9.45 inches)

Weight:
3.7 kg (8.16 lbs)

Power

Power consumption:
12 V, 1 A maximum

System Requirements

Recommended:
Windows XP / Windows 7
Intel Core i5 / Core i7
3GB RAM or higher
Built-in Intel USB 2.0 controller

Accessories

1.25/PC holder

SMX-F-1.25/PC1.25/PC connector fixture for measuring LC and MU connectors with PC end face.
Used with SMX-QS04-B, SMX-7QS-T, SMX-7QS, SMX-8QM-B

MU/APC holder

SMX-F-1.25/APC-MUMU/APC connector fixture for measuring MU connectors with APC end face.
Used with SMX-QS04-B, SMX-7QS-T, SMX-7QS, SMX-8QM-B

LC/APC holder

SMX-F-1.25/APC-LCLC/APC connector fixture for measuring LC connectors with APC end face.
Used with SMX-QS04-B, SMX-7QS-T, SMX-7QS, SMX-8QM-B

 
SMX-F-1.25/APC Ar

SMX-F-1.25/APC-Ar1.25/APC connector fixture for measuring 1.25 mm ARINC 801 connectors with APC end face (with 30° key).
Used with SMX-QS04-B, SMX-7QS-T, SMX-7QS, SMX-8QM-B

1.25/PC holder

SMX-F-1.6/PC1.6/PC connector fixture for measuring 1.6 mm connectors with PC end face.
Used with SMX-QS04-B, SMX-7QS-T, SMX-7QS, SMX-8QM-B

LC/APC holder

SMX-F-2/PC2.0/PC connector fixture for measuring 2.0 mm connectors with PC end face.
Used with SMX-QS04-B, SMX-7QS-T, SMX-7QS, SMX-8QM-B

 
LC/APC holder

SMX-F-2.5/PC2.5/PC connector fixture for measuring SC, FC and ST connectors with PC end face.
Used with SMX-QS04-B, SMX-7QS-T, SMX-7QS, SMX-8QM-B

SC/APC holder

SMX-F-2.5/APC-SCSC/APC connector fixture for measuring SC connectors with APC end face.
Used with SMX-QS04-B, SMX-7QS-T, SMX-7QS, SMX-8QM-B

FC/APC

SMX-F-2.5/APC-FC-RSMX-F-2.5/APC-FC-NFC/APC-R connector fixture for measuring FC connectors of type R (key width is 2 mm) with APC end face.
FC/APC-N connector fixture for measuring FC connectors of type N (key width is 2.14 mm) with APC end face.
Used with SMX-QS04-B, SMX-7QS-T, SMX-7QS, SMX-8QM-B

 
LC/PC Duplex

SMX-F-LC/PC-DLC/PC Duplex connector fixture for measuring LC Duplex connectors with PC end face.
Used with SMX-QS04-B, SMX-7QS-T, SMX-7QS, SMX-8QM-B

E2000/PC holder

SMX-F-E2000/PCE2000/PC connector fixture for measuring E2000 connectors with PC end face.
Used with SMX-QS04-B, SMX-7QS-T, SMX-7QS, SMX-8QM-B

E2000/APC holder

SMX-F-E2000/APCE2000/APC connector fixture for measuring E2000 connectors with APC end face.
Used with SMX-QS04-B, SMX-7QS-T, SMX-7QS, SMX-8QM-B

 

* using fractional field of view

Sample Images

SC/PC connector Measurement Results: Surface 3D view

SC/PC connector Measurement Results: Surface 3D view

SC/PC connector Measurement Results: Surface 3D view (magnified)

SC/PC connector Measurement Results: Surface 3D view (magnified)

SC/PC connector Measurement Results: Subtracted Surface 2D View (magnified)

SC/PC connector Measurement Results: Subtracted Surface 2D View (magnified)


SC/PC connector Measurement Results: Surface 3D view

SC/PC connector Measurement Results: Surface 3D view

0.5, 0.75, 1, 2 um lines etched on fiber by X-ray lithography

0.5, 0.75, 1, 2 µm lines etched on fiber by X-ray lithography

Measurement Summary Report

Measurement Summary Report


Measurement results of an LC/PC connector with defects: 3D view and Measurement Report

Measurement results of an LC/PC connector with defects: 3D view and Measurement Report